The pipe is sized from velocity, never from the pump. Choose the bore so the water moves at a sensible speed, work out what that costs you in friction, and only then go looking for a pump.
The panel opposite runs the same correlations as the H-100 design sheet, so the animation and the calculator cannot disagree. Every parameter below is live — drag one and the picture responds.
| Parameter | Unit | Default | Range |
|---|---|---|---|
| Pipe material | |||
| Material | Ductile iron | 6 options | |
| Selecting a material sets the design roughness below. The quoted values are aged, not as-new — designing iron on 0.03 mm is how pumps end up undersized. | |||
| Duty | |||
| Flow | m³/h | 120 | 5 – 800 |
| Internal diameter | mm | 150 | 25 – 600 |
| Developed length | m | 180 | 5 – 2,000 |
| Roughness (override) | mm | 0.1 | 0.001 – 3 |
| Σ K, fittings | – | 8 | 0 – 60 |
| Temperature | °C | 20 | 1 – 90 |
Open the full H-100 design sheet for the governing equations, the accepted design envelopes and the worked calculation.
A first pass on the main variables.
Selecting a material sets the design roughness below. The quoted values are aged, not as-new — designing iron on 0.03 mm is how pumps end up undersized.